Specifications Table for FXUA-A

FXUA50AVEB FXUA71AVEB FXUA100AVEB FXUA50AVMB (Archived) (Preliminary) FXUA71AVMB (Archived) (Preliminary) FXUA100AVMB (Archived) (Preliminary)
Sound pressure level Heating At high fan speed dBA 37.0 40.0 47.0 37 40.0 47.0
    At low fan speed dBA 33.0 36.0 40.0 33 36.0 40.0
    At medium fan speed dBA 35.0 38.0 44.0 35 38.0 44.0
  Cooling At low fan speed dBA 33.0 36.0 40.0 33 36.0 40.0
    At high fan speed dBA 37.0 40.0 47.0 37 40.0 47.0
    At medium fan speed dBA 35.0 38.0 44.0 35 38.0 44.0
Refrigerant GWP   675 675 675 675 675 675
  Type   R-32 R-32 R-32 R-32 R-32 R-32
Power input - 50Hz Cooling At high fan speed kW 0.029 0.055 0.117 0.050 0.090 0.200
  Heating At high fan speed kW 0.029 0.055 0.117
Cooling capacity Total capacity At high fan speed kW 5.6 8.0 11.2 5.6 8.0 11.2
  Nom. kW 5.6 8.0 11.2
Piping connections Liquid OD mm 6.4 6.4 9.5 6.35 6.35 9.52
    Type   Flare connection Flare connection Flare connection
  Gas OD mm 12.7 12.7 15.9 12.7 12.7 12.9
    Type   Flare connection Flare connection Flare connection
  Drain   VP20 VP20 VP20 I.D. 20/O.D. 26 I.D. 20/O.D. 26 I.D. 20/O.D. 26
Sound power level Cooling At high fan speed dBA 55.0 58.0 65.0 55 58 65
Air filter Type   Resin net Resin net Resin net Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance
Dimensions Unit Width mm 950 950 950 950 950 950
    Depth mm 950 950 950 950 950 950
    Height mm 198 198 198 198 198 198
Casing Material   Resin Resin Resin Resin Resin Resin
  Colour   Fresh White Fresh White Fresh White
Weight Unit kg 27 27 28 26 26 27
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min 17.0 22.5 31.0 17 22.5 31.0
      At low fan speed m³/min 13.0 16.0 21.0 13 16.0 21.0
Heating capacity Total capacity At high fan speed kW 6.3 9.0 12.5 6.3 9.0 12.5
  Nom. kW 6.3 9.0 12.5
Current - 50Hz Maximum fuse amps (MFA) A 6 6 6 16 16 16
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220-230 220-240/220-230 220-240/220-230
Notes       (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases
Standard Accessories Thermal insulation tube 3 3 3
  Sealing material 4 4 4
  Wire clamp material 10 10 10
  Drain hose 1 1 1
  Hose band 1 1 1
  Drain joint 1 1 1
  Washer fixing plate 1 1 1
  Extension auxiliary pipe 1 1 1
  Non woven fabric 1 1 1
  Screws 5 5 5
  Washer 8 8 8
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - The sound power level is an absolute value indicating the power which a sound source generates. (3) - The sound power level is an absolute value indicating the power which a sound source generates. (3) - The sound power level is an absolute value indicating the power which a sound source generates.
  (4) - Instead of a fuse, use a circuit breaker (4) - Instead of a fuse, use a circuit breaker (4) - Instead of a fuse, use a circuit breaker
  (5) - Select wire size based on the value of MCA (5) - Select wire size based on the value of MCA (5) - Select wire size based on the value of MCA
  (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases