| FVXG25K2V1B / RXG25K2V1B | FVXG25K2V1B / RXG25K3V1B | FVXG35K2V1B / RXG35K2V1B | FVXG35K2V1B / RXG35K3V1B | FVXG50K2V1B / RXG50K2V1B | FVXG50K2V1B / RXG50K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | |
| Max. | kW | 3.0 | 3.0 | 3.8 | 3.8 | 5.6 | 5.6 | ||
| Nom. | kW | 2.5 (3) | 2.5 (2) | 3.5 (3) | 3.5 (2) | 5.0 (3) | 5.0 (2) | ||
| Space cooling | SEER | 6.46 | 6.33 | 5.31 | |||||
| Annual energy consumption | kWh/a | 135 | 194 | 330 | |||||
| Capacity | Pdesign | kW | 2.50 | 3.50 | 5.00 | ||||
| Energy efficiency class | A++ | A++ | A | ||||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.80 | 3.10 | 4.60 | |||
| SCOP/A | 4.56 | 3.93 | 4.13 | ||||||
| Energy efficiency class | A+ | A | A+ | ||||||
| Annual energy consumption | kWh/a | 858 | 1,103 | 1,559 | |||||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
| Gas | OD | mm | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | |
| Drain | OD | mm | 18 | 18 | 18 | 18 | 18 | 18 | |
| Nominal efficiency | EER | 4.55 | 4.55 | 3.68 | 3.68 | 3.29 | 3.29 | ||
| Annual energy consumption | kWh | 275 | 275 | 475 | 475 | 760 | 760 | ||
| COP | 4.36 | 4.36 | 3.72 | 3.72 | 3.67 | 3.67 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 3.4 (4) | 3.4 (3) | 4.5 (4) | 4.5 (3) | 5.8 (4) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | ||
| Max. | kW | 4.5 | 4.5 | 5.0 | 5.0 | 8.1 | 8.1 | ||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | ||||
| (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | ||||
| (5) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (5) - 220V | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (5) - 220V | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (5) - 220V | ||||
| (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (6) - 230V | (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (6) - 230V | (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | (6) - 230V | ||||
| (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | ||||
| (8) - 230V | (8) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | (8) - 230V | (8) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | (8) - 230V | (8) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | ||||
| (9) - 240V | (9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (9) - 240V | (9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (9) - 240V | (9) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| (10) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | (10) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | (10) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | |||||||
| (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||||