| FVA71AMVEB / RZQSG71L3V1B | FVA100AMVEB / RZQSG100L9V1B | FVA125AMVEB / RZQSG125L9V1B | FVA140AMVEB / RZQSG140L9V1B | ||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 6.80 | 9.50 | 12.00 | 13.40 | |
| Space cooling | SEER | 5.50 | 5.50 | 5.50 | 5.31 | ||
| Annual energy consumption | kWh/a | 433 | 605 | 764 | 1,515 | ||
| Capacity | Pdesign | kW | 6.80 | 9.50 | 12.00 | 13.40 | |
| Energy efficiency class | A | A | A | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 6.33 | 7.60 | 7.60 | 11.47 |
| SCOP/A | 3.86 | 4.01 | 3.85 | 3.69 | |||
| Energy efficiency class | A | A+ | A | ||||
| Annual energy consumption | kWh/a | 2,297 | 2,654 | 2,764 | 4,350 | ||
| Nominal efficiency | EER | 3.21 | 3.21 | 2.81 | 2.51 | ||
| Annual energy consumption | kWh | 1,059 | 1,480 | 2,135 | |||
| COP | 3.61 | 3.61 | 3.41 | 3.41 | |||
| Energy labeling Directive | Cooling | A | A | C | |||
| Heating | A | A | B | ||||
| Heating capacity | Nom. | kW | 7.50 | 10.80 | 13.50 | 15.50 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||