| FTXM20N2V1B / FTXM20N2V1B / 3MXM40N2V1B | FTXM25N2V1B / FTXM25N2V1B / 3MXM52N2V1B | FTXM20N2V1B / FTXM20N2V1B / FTXM25N2V1B / 3MXM68N2V1B | FTXM20N2V1B / FTXM25N2V1B / FTXM25N2V1B / 3MXM68N2V1B | FTXM20N2V1B / FTXM50N2V1B / 3MXM68N2V1B | FTXM25N2V1B / FTXM42N2V1B / 3MXM68N2V1B | FTXM35N2V1B / FTXM35N2V1B / 3MXM68N2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 4.00 | 5.0 | 6.5 | 6.8 | 6.8 | 6.7 | 6.8 | |
| Space cooling | SEER | 8.52 | 8.59 | 7.76 | 7.71 | 7.78 | 7.99 | 8.02 | ||
| Annual energy consumption | kWh/a | 165 | 204 | 294 | 309 | 306 | 294 | 297 | ||
| Capacity | Pdesign | kW | 4.00 | 5.00 | 6.50 | 6.80 | 6.80 | 6.70 | 6.80 | |
| Energy efficiency class | A+++ | A+++ | A++ | A++ | A++ | A++ | A++ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 4.80 | 4.80 | 5.30 | 5.30 | 4.50 | 4.30 | 4.80 |
| SCOP/A | 4.24 | 4.38 | 4.09 | 4.10 | 3.90 | 3.86 | 4.00 | |||
| Energy efficiency class | A+ | A+ | A+ | A+ | A | A | A+ | |||
| Pdh Heating capacity at -10° | kW | 3.60 | ||||||||
| Annual energy consumption | kWh/a | 1,582 | 1,533 | 1,814 | 1,807 | 1,612 | 1,559 | 1,680 | ||
| Nominal efficiency | Annual energy consumption | kWh | 420 | 515 | 810 | 883 | 794 | 751 | 723 | |
| EER | 4.76 | 4.85 | 4.01 | 3.85 | 4.28 | 4.46 | 4.70 | |||
| COP | 4.73 | 4.45 | 4.49 | 4.38 | 3.82 | 3.95 | 3.81 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 4.60 | 6.80 | 8.20 | 8.60 | 8.60 | 8.30 | 8.60 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||