Specifications Table for FTXM-N / 2MXM-M

FTXM20N2V1B / FTXM20N2V1B / 2MXM40M4V1B FTXM20N2V1B / FTXM25N2V1B / 2MXM40M4V1B FTXM20N2V1B / FTXM35N2V1B / 2MXM40M4V1B FTXM25N2V1B / FTXM25N2V1B / 2MXM40M4V1B FTXM25N2V1B / FTXM35N2V1B / 2MXM40M4V1B
Cooling capacity Nom. kW 4.00 4.00 4.00 4.00 4.00
Space cooling SEER   8.53 8.50 8.19 8.36 8.11
  Annual energy consumption kWh/a 165 165 171 168 173
  Capacity Pdesign kW 4.00 4.00 4.00 4.00 4.00
  Energy efficiency class   A+++ A+++ A++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 3.20 3.20 3.20 3.20 3.20
  SCOP/A   4.64 4.60 4.60 4.60 4.61
  Energy efficiency class   A++ A++ A++ A++ A++
  Pdh Heating capacity at -10° kW 2.55 2.56 2.58 2.57 2.59
  Annual energy consumption kWh/a 966 973 974 974 971
Nominal efficiency Annual energy consumption kWh 485 481 476 478 472
  EER   4.12 4.16 4.20 4.18 4.24
  COP   4.28 4.32 4.41 4.37 4.46
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Heating capacity Nom. kW 4.20 4.20 4.20 4.20 4.20
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data