| FTXM20M2V1B / FTXM20M2V1B / 2MXM40M2V1B | FTXM20M2V1B / FTXM20M2V1B / 2MXM40M3V1B | FTXM20M2V1B / FTXM25M2V1B / 2MXM40M2V1B | FTXM20M2V1B / FTXM25M2V1B / 2MXM40M3V1B | FTXM20M2V1B / FTXM35M2V1B / 2MXM40M2V1B | FTXM20M2V1B / FTXM35M2V1B / 2MXM40M3V1B | FTXM25M2V1B / FTXM25M2V1B / 2MXM40M2V1B | FTXM25M2V1B / FTXM25M2V1B / 2MXM40M3V1B | FTXM25M2V1B / FTXM35M2V1B / 2MXM40M2V1B | FTXM25M2V1B / FTXM35M2V1B / 2MXM40M3V1B | FTXM20M2V1B / FTXM20M2V1B / 2MXM50M2V1B | FTXM20M2V1B / FTXM25M2V1B / 2MXM50M2V1B | FTXM20M2V1B / FTXM35M2V1B / 2MXM50M2V1B | FTXM20M2V1B / FTXM42M2V1B / 2MXM50M2V1B | FTXM20M2V1B / FTXM50M2V1B / 2MXM50M2V1B | FTXM25M2V1B / FTXM25M2V1B / 2MXM50M2V1B | FTXM25M2V1B / FTXM35M2V1B / 2MXM50M2V1B | FTXM25M2V1B / FTXM42M2V1B / 2MXM50M2V1B | FTXM25M2V1B / FTXM50M2V1B / 2MXM50M2V1B | FTXM35M2V1B / FTXM35M2V1B / 2MXM50M2V1B | FTXM35M2V1B / FTXM42M2V1B / 2MXM50M2V1B | FTXM35M2V1B / FTXM50M2V1B / 2MXM50M2V1B | FTXM42M2V1B / FTXM42M2V1B / 2MXM50M2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 4.00 | 4.0 | 4.00 | 4.0 | 4.00 | 4.0 | 4.00 | 4.0 | 4.00 | 4.0 | 4.00 | 4.50 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | |
| Space cooling | SEER | 8.53 | 8.53 | 8.50 | 8.50 | 8.19 | 8.19 | 8.36 | 8.36 | 8.11 | 8.11 | 8.71 | 8.67 | 8.54 | 8.54 | 8.51 | 8.53 | 8.56 | 8.57 | 8.52 | 8.57 | 8.60 | 8.52 | 8.56 | ||
| Annual energy consumption | kWh/a | 165 | 165 | 165 | 165 | 171 | 171 | 168 | 168 | 173 | 173 | 161 | 182 | 205 | 205 | 206 | 205 | 205 | 204 | 206 | 205 | 204 | 206 | 205 | ||
| Capacity | Pdesign | kW | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 4.50 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | |
| Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A++ | A++ | A++ | A++ | A++ | A++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 3.20 | 3.20 | 3.20 | 3.20 | 3.20 | 3.20 | 3.20 | 3.20 | 3.20 | 3.20 | 4.00 | 4.10 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 |
| SCOP/A | 4.64 | 4.64 | 4.60 | 4.60 | 4.60 | 4.60 | 4.60 | 4.60 | 4.61 | 4.61 | 4.61 | 4.61 | 4.61 | 4.63 | 4.68 | 4.61 | 4.62 | 4.65 | 4.71 | 4.66 | 4.67 | 4.75 | 4.70 | |||
| Energy efficiency class | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | |||
| Pdh Heating capacity at -10° | kW | 2.6 | 3 | 2.7 | 3 | 2.8 | 3 | 2.7 | 3 | 2.8 | 3 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | ||
| Annual energy consumption | kWh/a | 966 | 966 | 973 | 973 | 974 | 974 | 974 | 974 | 971 | 971 | 1,214 | 1,244 | 1,275 | 1,268 | 1,255 | 1,275 | 1,272 | 1,265 | 1,249 | 1,262 | 1,258 | 1,238 | 1,251 | ||
| Nominal efficiency | Annual energy consumption | kWh | 486 | 486 | 481 | 481 | 477 | 477 | 479 | 479 | 472 | 472 | 471 | 535 | 619 | 615 | 609 | 624 | 616 | 612 | 606 | 609 | 604 | 599 | 601 | |
| EER | 4.12 | 4.12 | 4.16 | 4.16 | 4.20 | 4.20 | 4.18 | 4.18 | 4.24 | 4.24 | 4.25 | 4.21 | 4.04 | 4.07 | 4.11 | 4.01 | 4.06 | 4.09 | 4.13 | 4.11 | 4.14 | 4.18 | 4.16 | |||
| COP | 4.28 | 4.28 | 4.32 | 4.32 | 4.41 | 4.41 | 4.37 | 4.37 | 4.46 | 4.46 | 4.09 | 4.10 | 4.12 | 4.13 | 4.15 | 4.08 | 4.05 | 4.03 | 3.98 | 4.01 | 4.00 | 3.94 | 3.98 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 5.60 | |||||||||||||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used. | |||||||||||||||||||||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||||||||||||||||||||
| Heating capacity | Min. | kW | 5.20 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | 5.60 | ||||||||||||
| Notes | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||||||||||||