| FTXJ20MV1BS / FTXJ20MV1BS / 3MXM40N2V1B | FTXJ20MV1BS / FTXJ20MV1BS / FTXJ20MV1BS / 3MXM40N2V1B | FTXJ20MV1BW / FTXJ20MV1BS / 3MXM40N2V1B | FTXJ20MV1BS / FTXJ20MV1BS / 3MXM52N2V1B | FTXJ20MV1BS / FTXJ20MV1BS / FTXJ20MV1BS / 3MXM52N2V1B | FTXJ20MV1BS / FTXJ20MV1BS / 3MXM68N2V1B | FTXJ20MV1BS / FTXJ20MV1BS / FTXJ20MV1BS / 3MXM68N2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 4.00 | 4.00 | 4.0 | 4.00 | 5.20 | 4.00 | 6.00 | |
| Space cooling | SEER | 7.62 | 7.46 | 7.62 | 7.72 | 7.70 | 5.42 | 6.23 | ||
| Annual energy consumption | kWh/a | 164 | 188 | 164 | 182 | 237 | 258 | 337 | ||
| Capacity | Pdesign | kW | 4.00 | 4.00 | 4.00 | 4.00 | 5.20 | 4.00 | 6.00 | |
| Energy efficiency class | A++ | A++ | A++ | A++ | A++ | A | A++ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 4.80 | 5.00 | 4.80 | 4.80 | 5.00 | 3.20 | 5.30 |
| SCOP/A | 4.11 | 4.18 | 4.11 | 4.11 | 4.18 | 3.87 | 4.00 | |||
| Energy efficiency class | A+ | A+ | A+ | A+ | A+ | A | A+ | |||
| Pdh Heating capacity at -10° | kW | 3.58 | 1.00 | 3.8 | 1.0 | 1.0 | 2.80 | 4.13 | ||
| Annual energy consumption | kWh/a | 1,632 | 1,672 | 1,632 | 1,632 | 1,672 | 1,157 | 1,852 | ||
| Nominal efficiency | Annual energy consumption | kWh | 482 | 467 | 482 | 471 | 593 | 457 | 787 | |
| EER | 4.15 | 4.28 | 4.15 | 4.25 | 4.38 | 4.38 | 3.81 | |||
| COP | 3.95 | 4.32 | 3.95 | 4.05 | 4.42 | 4.04 | 3.88 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 4.60 | 4.60 | 4.60 | 6.80 | 6.80 | 6.50 | 7.80 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used. | ||||||||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | |||||||||
| (3) - See separate drawing for operation range | ||||||||||
| (4) - See separate drawing for electrical data | ||||||||||