| FHQ35CAVEB / RXL35K2V1B | FHQ50CAVEB / RXL50K2V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.4 | 1.7 | |
| Max. | kW | 4.0 | 5.8 | ||
| Nom. | kW | 3.40 | 5.00 | ||
| Space cooling | SEER | 5.32 | 5.54 | ||
| Annual energy consumption | kWh/a | 224 | 316 | ||
| Capacity | Pdesign | kW | 3.40 | 5.00 | |
| Energy efficiency class | A | A | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 3.10 | 4.35 |
| SCOP/A | 4.17 | 3.81 | |||
| Energy efficiency class | A+ | A | |||
| Annual energy consumption | kWh/a | 1,039 | 1,600 | ||
| Nominal efficiency | EER | 3.58 | 3.18 | ||
| Annual energy consumption | kWh | 475 | 785 | ||
| COP | 3.96 | 3.35 | |||
| Energy labeling Directive | Cooling | A | B | ||
| Heating | A | C | |||
| Heating capacity | Nom. | kW | 4.00 | 6.00 | |
| Min. | kW | 1.3 | 1.6 | ||
| Max. | kW | 5.1 | 6.8 | ||
| Notes | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||