| FHA35AVEB9 / RXM35R5V1B | FHA50AVEB9 / RXM50R5V1B | FHA50AVEB9 / RXM50R2V1B | FHA50AVEB98 / RXM50R5V1B | FHA50AVEB99 / RXM50R5V1B | FHA50AVEB99 / RXM50R2V1B | FHA60AVEB9 / RXM60R2V1B | FHA60AVEB9 / RXM60R5V1B | FHA60AVEB98 / RXM60R5V1B | FHA60AVEB99 / RXM60R5V1B | FHA60AVEB99 / RXM60R2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 3.40 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.70 | 5.70 | 5.70 | 5.70 | 5.70 | |
| Heating capacity | Nom. | kW | 4.00 | 6.00 | 6.00 | 6.00 | 6.00 | 6.00 | 7.20 | 7.20 | 7.20 | 7.20 | 7.20 | |
| Nominal efficiency | Annual energy consumption | kWh | 456 | 779 | 779 | 779 | 779 | 779 | 866 | 866 | 866 | 866 | 866 | |
| COP | 4.08 | 3.35 | 3.35 | 3.35 | 3.35 | 3.35 | 3.32 | 3.32 | 3.32 | 3.32 | 3.32 | |||
| EER | 3.73 | 3.21 | 3.21 | 3.21 | 3.21 | 3.21 | 3.29 | 3.29 | 3.29 | 3.29 | 3.29 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | A | A | A | A | ||
| Heating | A | C | C | C | C | C | C | C | C | C | C | |||
| Space cooling | Annual energy consumption | kWh/a | 191 | 295 | 295 | 295 | 295 | 295 | 328 | 328 | 328 | 328 | 328 | |
| Energy efficiency class | A++ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Capacity | Pdesign | kW | 3.40 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.70 | 5.70 | 5.70 | 5.70 | 5.70 | |
| SEER | 6.24 | 5.92 | 5.92 | 5.92 | 5.92 | 5.92 | 6.08 | 6.08 | 6.08 | 6.08 | 6.08 | |||
| Space heating (Average climate) | Annual energy consumption | kWh/a | 979 | 1,577 | 1,577 | 1,577 | 1,577 | 1,577 | 1,704 | 1,704 | 1,704 | 1,704 | 1,704 | |
| Capacity | Pdesign | kW | 3.10 | 4.35 | 4.35 | 4.35 | 4.35 | 4.35 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | |
| Energy efficiency class | A+ | A | A | A | A | A | A | A | A | A | A | |||
| Pdh Heating capacity at -10° | kW | 3.85 | 3.85 | 3.85 | 3.85 | 3.85 | 4.08 | 4.08 | 4.08 | 4.08 | 4.08 | |||
| SCOP/A | 4.43 | 3.86 | 3.86 | 3.86 | 3.86 | 3.86 | 3.87 | 3.87 | 3.87 | 3.87 | 3.87 | |||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||