| FFA25A2VEB9 / RXM25A5V1B9 | FFA35A2VEB9 / RXM35A5V1B9 | FFA50A2VEB9 / RXM50A5V1B9 | ||||
|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 2.5 | 3.4 | 5 | |
| Heating capacity | Nom. | kW | 3.2 | 4.2 | 5.8 | |
| Nominal efficiency | EER | 4.57 | 3.81 | 3.24 | ||
| COP | 3.9 | 3.5 | 3.49 | |||
| Annual energy consumption | kWh | 274 | 446 | 772 | ||
| Energy labeling Directive | Cooling | A | A | A | ||
| Heating | A | B | B | |||
| Space cooling | Energy efficiency class | A++ | A++ | A+ | ||
| Capacity | Pdesign | kW | 2.5 | 3.4 | 5 | |
| SEER | 6.32 | 6.47 | 5.98 | |||
| Annual energy consumption | kWh/a | 138 | 184 | 293 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | A+ | A | ||
| Capacity | Pdesign | kW | 2.31 | 3.1 | 3.84 | |
| SCOP/A | 4.29 | 4.19 | 3.9 | |||
| Pdh Heating capacity at -10° | kW | 1.84 | 2.5 | 3.4 | ||
| Annual energy consumption | kWh/a | 754 | 1035 | 1378 | ||
| Notes | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - See separate drawing for operation range | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - See separate drawing for electrical data | ||||