| FDXM35F3V1B9 / FDXM35F3V1B9 / FDXM35F3V1B9 / RZQSG100L8Y1B | FDXM50F3V1B9 / FDXM50F3V1B9 / RZQSG100L8Y1B | FDXM35F3V1B9 / FDXM35F3V1B9 / FDXM35F3V1B9 / FDXM35F3V1B9 / RZQSG125L8Y1B | FDXM50F3V1B9 / FDXM50F3V1B9 / FDXM50F3V1B9 / RZQSG125L8Y1B | FDXM60F3V1B9 / FDXM60F3V1B9 / RZQSG125L8Y1B | ||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 9.5 | 9.5 | 12.0 | 12.0 | 12.0 | |
| Space cooling | SEER | 4.80 | 5.10 | 4.80 | 4.80 | 4.80 | ||
| Annual energy consumption | kWh/a | 693 | 652 | 875 | 875 | 875 | ||
| Capacity | Pdesign | kW | 9.50 | 9.50 | 12.00 | 12.00 | 12.00 | |
| Energy efficiency class | B | A | B | B | B | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 7.10 | 7.60 | 7.60 | 7.60 | 7.60 |
| SCOP/A | 3.80 | 3.80 | 3.80 | 3.80 | 3.80 | |||
| Energy efficiency class | A | A | A | A | A | |||
| Annual energy consumption | kWh/a | 2,616 | 2,800 | 2,800 | 2,800 | 2,800 | ||
| Nominal efficiency | EER | 2.56 | 3.02 | 2.57 | 2.57 | 2.46 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||