| FDQ125C5VEB | FDQ125C7VEB | ||||
|---|---|---|---|---|---|
| Sound pressure level | Heating | High | dBA | 40 | 40 |
| Low | dBA | 33 | 33 | ||
| Cooling | Low | dBA | 33 | 33 | |
| High | dBA | 40 | 40 | ||
| Control systems | Wired remote control | BRC1D52, BRC1E53A, BRC1E53B, BRC1E53C | BRC1D52, BRC1E53A, BRC1E53B, BRC1E53C, BRC1D528 | ||
| Infrared remote control | BRC4C65 | BRC4C65 | |||
| Cooling capacity | Total capacity | Nom. | kW | 12.5 (1) | 12.5 |
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 |
| Gas | OD | mm | 15.9 | 15.9 | |
| Drain | VP25 (I.D. 25/O.D. 32) | VP25 (I.D. 25/O.D. 32) | |||
| Required ceiling void > | mm | 350 | 350 | ||
| Power input | Cooling | Nom. | kW | 0.35 | |
| Heating | Nom. | kW | 0.35 | ||
| Sound power level | Cooling | dBA | 66 | 66 | |
| Dimensions | Unit | Width | mm | 1,400 | 1,400 |
| Depth | mm | 700 | 700 | ||
| Height | mm | 300 | 300 | ||
| Casing | Material | Galvanised steel | |||
| Colour | Not painted (galvanised) | Not painted | |||
| Weight | Unit | kg | 45 | 45 | |
| Fan | External static pressure | High | Pa | 200 | 200 |
| Nom. | Pa | 50 | 50 | ||
| Drain-up height | mm | 625 | 625 | ||
| Decoration panel | Weight | kg | 6.5 | 6.5 | |
| Model | BYBS125DJW1 | BYBS125DJW1 | |||
| Dimensions | Height | mm | 55 | 55 | |
| Depth | mm | 500 | 500 | ||
| Width | mm | 1,500 | 1,500 | ||
| Colour | White (10Y9/0.5) | White (10Y9/0.5) | |||
| Heating capacity | Total capacity | Nom. | kW | 14.0 (2) | 14.0 |
| Power supply | Phase | 1~ | 1~ | ||
| Name | VE | VE | |||
| Frequency | Hz | 50/60 | 50/60 | ||
| Voltage | V | 220-240/220 | 220-240/220 | ||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | (1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | |||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | ||||
| (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - The sound pressure values are mentioned for a unit installed with rear suction. | ||||
| (4) - The sound pressure values are mentioned for a unit installed with rear suction. | (4) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | ||||
| (5) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (5) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m | ||||