| FAA71BUV1B / ARXM71A5V1B | ||||
|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 6.8 | |
| Max. | kW | 6.95 | ||
| Heating capacity | Nom. | kW | 7.5 | |
| Max. | kW | 7.59 | ||
| Nominal efficiency | EER | 3.4 | ||
| COP | 3.19 | |||
| Annual energy consumption | kWh | 1000 | ||
| Energy labeling Directive | Cooling | A | ||
| Heating | D | |||
| Space cooling | Energy efficiency class | A+ | ||
| Capacity | Pdesign | kW | 6.8 | |
| SEER | 5.77 | |||
| Annual energy consumption | kWh/a | 412 | ||
| Space heating (Average climate) | Energy efficiency class | A | ||
| Capacity | Pdesign | kW | 4.5 | |
| SCOP/A | 3.81 | |||
| Pdh Heating capacity at -10° | kW | 4.5 | ||
| Annual energy consumption | kWh/a | 1652 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | ||||