| AZQS71B2V1B | AZQS100B8V1B | AZQS125B8V1B | AZQS140B8V1B | |||||
|---|---|---|---|---|---|---|---|---|
| Dimensions | Unit | Height | mm | 770 | 990 | 990 | 1,430 | |
| Width | mm | 900 | 940 | 940 | 940 | |||
| Depth | mm | 320 | 320 | 320 | 320 | |||
| Weight | Unit | kg | 67 | 72.8 | 74.3 | 94.9 | ||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | |||
| Operation range | Cooling | Ambient | Min. | °CDB | -5 | -5.0 | -5.0 | -5.0 |
| Max. | °CDB | 46 | 46.0 | 46.0 | 46.0 | |||
| Heating | Ambient | Min. | °CWB | -15 | -15.0 | -15.0 | -15.0 | |
| Max. | °CWB | 15.5 | 15.5 | 15.5 | 15.5 | |||
| Sound power level | Cooling | dBA | 64 | 70.0 | 71.0 | 70.0 | ||
| Heating | dBA | 70.0 | 71.0 | 70.0 | ||||
| Sound pressure level | Cooling | Nom. | dBA | 48 | 53 | 54 | 53 | |
| Heating | Nom. | dBA | 50 | 57 | 58 | 54 | ||
| Night quiet mode | Level 1 | dBA | 43 | 49 | 49 | 49 | ||
| Refrigerant | Type | R-410A | R-410A | R-410A | R-410A | |||
| Charge | kg | 2.75 | 2.9 | 2.9 | 4.0 | |||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 | 9.52 | 9.52 | |
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | 15.9 | ||
| Piping length | OU - IU | Max. | m | 50 | 50, 30 (1) | 50, 30 (1) | 50, 30 (1) | |
| System | Equivalent | m | 70 | 70, 40 (1) | 70, 40 (1) | 70, 40 (1) | ||
| Chargeless | m | 30 | 30 | 30 | 30 | |||
| Additional refrigerant charge | kg/m | See installation manual | See installation manual | See installation manual | See installation manual | |||
| Level difference | IU - OU | Max. | m | 30.0 | 30.0 | 30.0 | 30.0 | |
| IU - IU | Max. | m | 0.5 | 0.5 | 0.5 | |||
| Standard Accessories | Tie-wraps | 2 | ||||||
| Installation manual | 1 | |||||||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | |||
| Current - 50Hz | Maximum fuse amps (MFA) | A | 32 | 32 | 40 | |||
| Notes | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - For combination with FCAG~AVEB indoor units | (1) - For combination with FCAG~AVEB indoor units | (1) - For combination with FCAG~AVEB indoor units | ||||
| (2) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A | (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | (2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | |||||
| (3) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB | (3) - Ssc: Short-circuit power | (3) - Ssc: Short-circuit power | (3) - Ssc: Short-circuit power | |||||
| (4) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). | (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||
| (5) - Contains fluorinated greenhouse gases | (5) - See separate drawing for electrical data | (5) - See separate drawing for electrical data | (5) - See separate drawing for electrical data | |||||
| (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | ||||||